Measurement systems that require linearity verification
Measurement systems that require linearity verifications
The following linearity verification protocol shall be used
max generally refers to the maximum reference value used during the linearity verification.
min refers to the minimum reference value used during the linearity verification
The linearity verification shall be run for each normally used operating range with the following steps
The linearity verification shall be run for each normally used operating range with the following steps
For conducting the linearity verification according to paragraph 9.2.1., the gas divider shall be accurate to within ± 1 per cent.
For conducting the linearity verification according to paragraph 9.2.1, the gas divider shall be accurate to within ± 1 per cent.
For conducting the linearity verification according to paragraph 9.2.1, the gas divider shall be accurate to within ± 1 per cent.
A linearity verification of the analyser shall be performed using propane in air and purified synthetic air according to paragraph 9.2.1.3.
A linearity verification of the analyzer shall be performed using propane in air and purified synthetic air according to paragraph 9.2.1.3.
A linearity verification of the analyzer shall be performed using propane in air and purified synthetic air according to paragraph 9.2.1.3.
The analytical balance used to determine the filter weight shall meet the linearity verification criterion of paragraph 9.2., table 6.
The analytical balance used to determine the filter weight shall meet the linearity verification criterion of paragraph 9.2, table 7.
The analytical balance used to determine the filter weight shall meet the linearity verification criterion of paragraph 9.2, Table 7.
This paragraph describes recommended methods for generating reference values for the linearity-verification protocol in paragraph 8.1.4.3. of this section.
A linearity verification shall be performed more frequently if the instrument manufacturer recommends it or based on good engineering judgment
The linearity check confirms that the curve (Light output vs ATP standard concentration) is linear from 0.01… Read More
For torque linearity verification, Tmax refers to the manufacturer's specified engine torque peak value of the highest torque engine to be tested.