Dictionnaire français - anglais

technologie et réglementation technique - iate.europa.eu
Optical tomography system: charge-coupled device linear image sensors... The developed system consists of a lighting system, a measurement section and a data acquisition system....
général - core.ac.uk - PDF: doaj.org
Optical tomography system based on charge-coupled device linear image sensors: particle size measurement... The developed system consists of a lighting system, a measurement section and a data acquisition system....
Optical tomography system: charge-coupled device linear image sensors... The developed system consists of a lighting system, a measurement section and a data acquisition system....
Pressure field in measurement section of wind tunnel... In order to confirm the quality of the wind inside of the measurement section, several measurements of the dynamic pressure have been performed with the Pitot-static tube....
 PDF: doaj.org
Control tasks in a water flow measurement sectionThis paper presents the control solutions for a water flow measurement section of a hydraulics laboratory....
tronçon de mesurage
technologie et réglementation technique - iate.europa.eu
L'ISO 5167-2:2003 est applicable uniquement à un écoulement qui reste subsonique dans tout le tronçon de mesurage et où le fluide peut être considéré comme monophasique.

ISO 5167-2:2003 is applicable only to a flow which remains subsonic throughout the measuring section and where the fluid can be considered as single phase.

général - CCMatrix (Wikipedia + CommonCrawl)
L'ISO 5167-2:2003 est applicable uniquement à un écoulement qui reste subsonique dans tout le tronçon de mesurage et où le fluide peut être considéré comme monophasique.

ISO 5167-4:2003 is applicable only to Venturi tubes in which the flow remains subsonic throughout the measuring section and where the fluid can be considered as single-phase.

général - CCMatrix (Wikipedia + CommonCrawl)
L'ISO 5167-2:2003 est applicable uniquement à un écoulement qui reste subsonique dans tout le tronçon de mesurage et où le fluide peut être considéré comme monophasique.

ISO 5167-3:2003 is applicable to nozzles and Venturi nozzles in which the flow remains subsonic throughout the measuring section and where the fluid can be considered as single-phase.

général - CCMatrix (Wikipedia + CommonCrawl)
L'ISO 5167-2:2003 est applicable uniquement à un écoulement qui reste subsonique dans tout le tronçon de mesurage et où le fluide peut être considéré comme monophasique.

ISO 5167 (all parts) is applicable only to flow that remains subsonic throughout the measuring section and where the fluid can be considered as single-phase.

général - CCMatrix (Wikipedia + CommonCrawl)
La présente partie de l'ISO 5167 est applicable uniquement à un écoulement qui reste subsonique dans tout le tronçon de mesurage et où le fluide peut être considéré comme monophasique.

This part of ISO 5167 is applicable only to cone meters in which the flow remains subsonic throughout the measuring section and where the fluid can be considered as single-phase.

général - CCMatrix (Wikipedia + CommonCrawl)
Measurement of section thickness in quantitative microscopy with special reference to enzyme histochemistry... In this investigation a simple, rapid, accurate, and reproducible technique is described for measuring section thickness using an instrument known as a Surfometer....
général - core.ac.uk - PDF: www.pubmedcentral.nih.gov
Investigation of flow resistance characteristics of endothermic hydrocarbon fuel under supercritical pressures ... The experiments are conducted by using a long tube measuring section and a short tube measuring section simultaneously in order to eliminate the effect of local pressure drop....
Investigation of flow resistance characteristics of endothermic hydrocarbon fuel under supercritical pressures... The experiments are conducted by using a long tube measuring section and a short tube measuring section simultaneously in order to eliminate the effect of local pressure drop....
 PDF: doaj.org
Development of wave absorbing system using an inclined porous plates... First one minimize the wave distortion in the measuring section by reducing the reflected wave generated from the opposite wall of wave tank....
Efficiency differences of upper and lower injectors and scan of tailrace temperature distributions... Temperature scans showed important vertical and horizontal temperature variation in the measuring section, because the measuring section was only two runner diameter downstream of the turbine....

Synonymes et termes associés français

Exemples français - anglais

sciences naturelles et appliquées / technologie et réglementation technique - iate.europa.eu
sciences naturelles et appliquées / technologie et réglementation technique - iate.europa.eu
sciences naturelles et appliquées / technologie et réglementation technique - iate.europa.eu
sciences naturelles et appliquées / technologie et réglementation technique - iate.europa.eu
technologie et réglementation technique - iate.europa.eu
[...]

Traductions en contexte français - anglais

ISO 5167-5:2016 est applicable uniquement aux cônes de mesure pour lesquels l'écoulement reste subsonique dans tout le tronçon de mesurage et où le fluide peut être considéré comme monophasique.

ISO 5167-2:2003 is applicable only to a flow which remains subsonic throughout the measuring section and where the fluid can be considered as single phase.

général - CCMatrix (Wikipedia + CommonCrawl)


1 milliard de traductions classées par domaine d'activité en 28 langues