Dictionnaire français - anglais

sciences naturelles et appliquées - iate.europa.eu
sciences naturelles et appliquées - iate.europa.eu
Dosimetric and kinetic parameters of lithium cadmium borate glasses doped with rare earth ions... The result clearly showed that europium doped cadmium borate glass has a potential to be considered as the thermoluminescence dosimeter....
général - core.ac.uk - PDF: doaj.org
Licensed under creative commons attribution cc by tl properties of x-ray irradiated li2o-mo-b2o3 (mo=zno, cao, cdo) glasses doped with europium ions... The result clearly showed that europium doped cadmium borate glass has a potential to be considered as the thermoluminescence dosimeter
Medical imaging: contribution toward background radiation and human exposure... In our study, we measured the entrance surface dose at different anatomical locations using thermoluminescence dosimeter in patients who underwent CT examinations and neurointerventional radiology procedures....
 PDF: doaj.org
Dosimetric and kinetic parameters of lithium cadmium borate glasses doped with rare earth ions ... The result clearly showed that europium doped cadmium borate glass has a potential to be considered as the thermoluminescence dosimeter
P-4a-272 1 evaluation of fading factor and self-dose... Among these detectors, the thermoluminescence dosimeter (TLD) has been generally adopted for environmental monitoring in nuclear facilities....
sciences naturelles et appliquées - iate.europa.eu
Dosimetric and kinetic parameters of lithium cadmium borate glasses doped with rare earth ions... The result clearly showed that europium doped cadmium borate glass has a potential to be considered as the thermoluminescence dosimeter....
général - core.ac.uk - PDF: doaj.org
Licensed under creative commons attribution cc by tl properties of x-ray irradiated li2o-mo-b2o3 (mo=zno, cao, cdo) glasses doped with europium ions... The result clearly showed that europium doped cadmium borate glass has a potential to be considered as the thermoluminescence dosimeter
Medical imaging: contribution toward background radiation and human exposure... In our study, we measured the entrance surface dose at different anatomical locations using thermoluminescence dosimeter in patients who underwent CT examinations and neurointerventional radiology procedures....
 PDF: doaj.org
Dosimetric and kinetic parameters of lithium cadmium borate glasses doped with rare earth ions ... The result clearly showed that europium doped cadmium borate glass has a potential to be considered as the thermoluminescence dosimeter
P-4a-272 1 evaluation of fading factor and self-dose... Among these detectors, the thermoluminescence dosimeter (TLD) has been generally adopted for environmental monitoring in nuclear facilities....
sciences naturelles et appliquées - iate.europa.eu
Dose reduction of cone beam ct scanning for the entire oral and maxillofacial regions with thyroid collars... Methods: Average tissue-absorbed dose for a NewTom 9000 CBCT scanner (Quantitative Radiology, Verona, Italy) was measured using thermoluminescent dosemeter chips in a phantom....
général - core.ac.uk - PDF: www.loc.gov

Publications scientifiques

Tld assessment of mouse dosimetry during microct imaging... Radiation dose was measured using thermoluminescent dosimeters (TLDs), which were irradiated employing an 80 kVp x-ray source, with 0.5...
industries nucléaire et électrique / sciences naturelles et appliquées / conditions et organisation du travail - core.ac.uk - PDF: www.pubmedcentral.nih.gov
Measurement of neutron flux and gamma dose rate distribution inside a water phantom for boron neutron capture therapy study at dalat research reactor... At Dalat Research Reactor, Vietnam, the neutron and gamma dose rate distribution inside a water phantom were measured by using activation method and Thermoluminescent Dosimeter (TLD) detector, respectively....
industries nucléaire et électrique / sciences naturelles et appliquées - core.ac.uk - PDF: journalarticle.ukm.my
Research on target tracking based on tld algorithm... This paper introduces the theoretical basis and the framework of improved algorithm of TLD(Tracking-Learning-Detection, TLD ) algorithm....
général - core.ac.uk - PDF: www.scientific.net
The use of lif (tld-100) as an out-of-field dosimeter... Although alternatives such as TLD-700 do not respond to neutrons, specialty dosimeters of this kind are expensive and are not routinely used in most clinics....
général - core.ac.uk - PDF: citeseerx.ist.psu.edu
Placement of tld on anaesthetized mouse.A: Cranial view showing TLD positions 1–7 (see table 2)....
général - core.ac.uk - PDF: figshare.com

Exemples français - anglais

santé / sciences naturelles et appliquées / technologie et réglementation technique - iate.europa.eu
santé / industries nucléaire et électrique / environnement - iate.europa.eu
industrie mécanique - lexique.mecaniqueindustrielle.com
[...]

Traductions en contexte français - anglais

Dans ce cas, la méthode la plus efficace pour surveiller les expositions du foetus est de mesurer la dose équivalente à la surface de l'abdomen à l'aide d'un dosimètre thermoluminescent.

In this case, the most effective method of monitoring exposures to the foetus, is to measure the equivalent dose to the surface of the abdomen using a thermoluminescent dosimeter.

général - CCMatrix (Wikipedia + CommonCrawl)


1 milliard de traductions classées par domaine d'activité en 28 langues