For establishing the values of cooling capacity, power input, energy efficiency ratio and seasonal energy performance ratio, measurements shall be made under the following conditions:
the seasonal energy performance ratio (SEPR) is not more than 10 % lower than the declared value, with point A measured at the rated cooling capacity
From 1 July 2016, the seasonal energy performance ratio (SEPR) of process chillers shall not fall below the following values:
The Ecodesign regulation also imposes new provisions regarding technical documentation and the publication of the coefficient of performance or the seasonal energy performance ratio.
All relevant performance data of the condensing unit, as well as the coefficient of performance or the seasonal energy performance ratio, is calculated based on these data.
the contribution of a back-up heater (if applicable) in the calculation of the seasonal efficiency of a unit in heating mode.
The seasonal energy performance ratio (SEPR) of condensing units with a rated cooling capacity higher than 2 kW at low temperature and 5 kW at medium temperature
At the date of entry into force of this Regulation, the best available technology on the market for process chillers in terms of seasonal energy performance ratio was identified as follows:
the seasonal energy efficiency ratio (SEER) and/or seasonal coefficient of performance (SCOP
seasonal energy efficiency ratio (SEER value), rounded up to one decimal
The determination of the seasonal energy consumption and efficiency for seasonal energy efficiency ratio (SEER) and seasonal coefficient of performance (SCOP) shall take into account
The determination of the seasonal energy consumption and seasonal energy efficiency ratio (SEER) and seasonal coefficient of performance (SCOP) shall take into account
for cooling mode: seasonal energy efficiency ratio (SEER value), rounded up to one decimal
the average of the three units for seasonal performance energy ratio (SEPR) is not more than 10 % lower than the declared value, with point A measured at the rated cooling capacity
the seasonal energy efficiency ratio SEER shall be calculated as the ratio of the reference annual cooling demand QC and the reference annual energy consumption for cooling QCE ;